Vehicle Loop Detector

Loop Diagnostics
Loop Isolation Transformer
Loop Conditioner
Aluminum RF Shield Housing
Surge Portection
Loop Frequences Counter
10 Gold Plated Sensitivity Controls
8 Gold Plated Function Controls
6 Gold Plated & Sealed Controls for Frequency, Reset & Frequency Counter

Two High Intensity LED Indicators

     
Technical Specifications
  Power: The detector is available in the following voltages, 12V AC/DC, 24V AC, 24V DC, 110 AC.
  Low Power: Detector is availabe with maximum current draw of 60mA
  Temperature: -40 F to +180 F
  Environmental Protection Circuit Board is conformally Coated
  Enclosure: Extruded anodized aluminum,
Height= 3.25 inches 83 mm - Width= 2.56 inches 40 mm- Depth = 3.65 inches 90 mm
  Output Relays 5A/125 V AC standard version, 1A/125 V AC low current version
  Connector: 86 CP11 compatible with 11 pin Octal DIN rail mountable socket or wire harness
  Surge Protection: The detector is protected with neon discharge lamps, zenner diods and surg arrestors
  Loop Input: Transformer isolated
  Grounded Loop: The Loop insolation transformer allows operation with poor quality loops
  Loop Inductance Range 20 to 2000 microhenries with Q factor of 5 or higher
  Tuning: Detector automatically tunes to the loop after power application or reset
  Tracking: Detector automatically tracks and compensates for environmental changes
  Power Indicator: Green LED solid light indicates power
  Loop Failure Indicator: Green LED blinks indicates loop problem
  Loop Failure Memory: Green LED blinks with fast consective blinks indicates past loop problem that healed
  Detect Indicator: Red LED Solid light indicates detection
  Extend Indicator: Red LED Blinks after a car left the loop indicates time extend feature
  Sensitivity: Is set by 10 position rotary switch
  Frequency: Is set three positon toggle switch
  Infinite Presence Mode: DIP switch selectable presence
  Limited 4 Minutes: DIP switch selectable presence
  Presence Time: DIP switch selectable
  Secod Presence Relay: DIP switch selectable
  Pulse on Exit / Entry: DIP switch selectable
  Fail Safe / Secure: DIP switch selectable
  Filter: DIP switch selectable 2 Seconds
  Extended Detection: DIP switch selectable 3, 6, and 9 seconds
 

 

automatic gate openers

automatic gate openers




automatic gate openers

automatic gate openers

automatic gate openers

Automatic gate openers are our business. Call us with further questions we are pleased to serve you. (800) 878-7829

8500 Hadden Rd. � Twinsburg O4408741 � 
Phone 800/878-7829 � FAX 330/650-9004

or email us at Customer Service

Quality work at low pricing