(800)878-7829 |
|||||||||||||||||||||||||||||||||||||
Multi-Door
Controller Model AM/II
|
|||||||||||||||||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
General Specifications Power
Operating Temperature
Memory All data memory is non-volatile EEPROM with
data retention in excess of 10 years; modular design to facilitate easy
transfer to another AM/II controller; memory modules available in four
capacities Which memory is right for you?
|
Outputs Relay: four form 'C" relays, rated at 3 amps with programmable output duration; all four can be configured for open/close; A and B can be supervised for status; C and D can be configured for control; all relay contacts have RFI, ARC, and lightning suppression. Wiegand: Wiegand compatible signals for adding RF capability to other access control systems; 26,30, and 31-bit formats are supported. RS232: one port for connection to a local computer printer, CRT, or modem; all communications are at 9600 baud LCD Display: integral two-line by 24-character backlit display for local programming and transaction monitoring LED Indicators: front panel indicators for all input and output activity for on-site troubleshooting. Inputs RF: 318 MHz superheterodyne receiver with -90 dBm sensitivity; built-in 20 dB adjustable attenuator for fine tuning radio performance Keypad/Reader: two sets of inputs for connecting six different keypads, card reader interfaces, or receivers Open Request: contact closure to ground activates channel A or B relays Door Sense/Inhibit: monitors status of a protected door or can be programmed to restrict access to relay 1 Programming: integral 17-key silicone rubber keypad for local programming Access Buttons: one button for each of the four relays; used to manually control relays Standard Equipment AM/II: four portal system controller; contains built-in receiver, RS232 port, and Wiegand outputs; accepts transmitters, keypads, and card readers as inputs; requires memory module and antenna Clock/Calendar Built-in 24-hour clock/calendar with battery back-up and daylight savings adjustment Connections All wiring connections to the unit are with plug-on, screw terminal blocks |
||||||||||||||||||||||||||||||||||||
AVAILABLE ACCESSORIES AM-Printer Serial Printer: allows
printing of real time event log and system reports (includes A2P printer
cable)
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|